1, anti-theft alarm system installation design the basic requirements

(1) Installation should be designed to be protective of the area under the protection requirements, select the appropriate detector type, model, etc.

(2) the effective protection under the detector area, the physical environment to determine the installation of the detector position, angle, height, requiring detectors in line with the requirements of protection possible under the conditions installed in hidden locations.

(3) the alignment should be concealed as much as possible, to avoid being destroyed. If you take the open wire line should be bad or plastic tubes to protect, and prevent rodents (such as rodents, etc.) damage.

(4) The construction drawings shall indicate the zone detectors and fiber optic cable line model specifications, and within the colored lines indicate the use of the cable.

(5) The construction drawings should save the record to facilitate system maintenance.

 

2, anti-theft alarm system installation and commissioning

(1) infrared detector installation process requirements

Installation should pay attention to the detector and the horizontal angle and height, this region has a great impact protection.

Avoid heat sources, such as hot and cold air outlet, air vent, heater, air conditioner and so on.

The scope of protection of the detector should be able to look straight, can not have obstacles.

Detector to avoid the straight on the doors and windows.

In order to ensure the antenna effect, set the transmitter antenna fully opened.

(2) Magnetic switch installation

Magnetic switch should open the door of the minimum angle to determine the installation location, magnets and magnetic switches of the distance can not exceed 10 mm. In order to ensure the antenna effect, set the transmitter antenna fully opened.

(3) the installation of alarm host

Alarm should be installed in the main hidden location, it should be noted on the front panel of the microphone and built-in speaker placement should not be covered, to ensure monitoring and alarm sound degree of sensitivity is not affected.

Alarm host a non-explosion-proof, can not be directly used Ⅰ, Ⅱ, Ⅲ grade hazardous locations (ie, have a certain concentration of flammable, explosive gas vapors, dust, fiber spaces), otherwise there may be dangerous!

Do not close the control panel TVs, air conditioners, computers, microwave ovens and other equipment in the vicinity of strong electromagnetic radiation, so as not to affect the antenna’s reception.

To ensure reliable operation of the alarm, the proposed configuration backup battery, the use of frequent power outages or blackouts area a long time, the proposed configuration larger capacity standby power.

In order to ensure the antenna reception, please pull all the receiving antenna.

Previous: From five to talk about the future optimization of smart home